Products

S6-EH1P(3-8)K-L-PLUS

  • Payment:

  • Warranty:

  • Cycle life:

Models
3K
3.6K
4.6K
5K
6K
8K
Input DC (PV side)
           
Recommended max. PV array size
6 kW
7.2 kW
9.2 kW
10 kW
12 kW
16 kW
Max. usable PV input power
4.8 kW
5.76 kW
7.36 kW
8 kW
9.6 kW
12.8 kW
Max. input voltage
500 V
Rated voltage
330 V
Start-up voltage
90 V
MPPT voltage range
90-435 V
Max. input current
16 A / 16 A
32 A / 32 A
Max. short circuit current
20 A / 20 A
40 A / 40 A
MPPT number/Max. input strings number
2/2
2/4
Battery
 
 
 
 
 
 
Battery type
Li-ion / Lead-acid
Battery voltage range
40-60 V
Max. charge / discharge power
3 kW
3.6 kW
4.6 kW
5 kW
6 kW
8 kW
Max. charge / discharge current 
70 A
80 A
105 A
112 A
135 A 
190 A
Communication
CAN/RS485
Output AC (Grid side)
 
 
 
 
 
 
Rated output power
3 kW
3.6 kW
4.6 kW
5 kW
6 kW
8 kW
Max. apparent output power
3 kVA
3.6 kVA
4.6 kVA
5 kVA
6 kVA
8 kVA
Operation phase
L/N/PE
Rated grid voltage
220 V / 230 V
Rated grid frequency
50 Hz / 60 Hz
Rated grid output current
13.7 A / 13.1 A
16.4 A / 15.7 A
20.9 A / 20 A
22.8 A / 21.8 A
27.3 A / 26.1 A
36.4 A / 34.8 A
Max. output current
13.7 A / 13.1 A
16.4 A / 15.7 A
20.9 A / 20 A
22.8 A / 21.8 A
27.3 A / 26.1 A
36.4 A / 34.8 A
Power factor
>0.99 (0.8 leading - 0.8 lagging)
THDi
<2%
Input AC (Grid side)
 
 
 
 
 
 
Input voltage range
187-253 V
Max. input current
21 A
25 A
29 A
32 A
40 A
50 A
Frequency range
45-55 Hz / 55-65 Hz
Output AC (Back-up)
 
 
 
 
 
 
Rated output power
3 kW
3.6 kW
4.6 kW
5 kW
6 kW
8 kW
Max. apparent output power
2 times of rated power, 10 s
Back-up switch time
<4 ms
Rated output voltage
L/N/PE, 220 V / 230 V
Rated frequency
50 Hz / 60 Hz
Rated output current
13.7 A / 13.1 A
16.4 A / 15.7 A
20.9 A / 20 A
22.8 A / 21.8 A
27.3 A / 26.1 A
36.4 A / 34.8 A
Max. AC Passthrough current
35 A
35 A
40 A
40 A
40 A
50 A
THDv (@linear load) 
<2%
Efficiency
 
 
 
 
 
 
Max. efficiency
96.2%
EU efficiency
96.1%
BAT charged by PV/AC Max. efficiency
95.3%/93.9%
BAT discharged to AC Max. efficiency
93.8%
Protection
 
Ground fault monitoring
Yes
DC reverse-polarity protection
Yes
Integrated AFCI 2.0
Optional
Protection class/Over voltage category
I / II (PV and BAT), III (MAINS and BACKUP and GEN)
General Data
 
Dimensions (W*H*D)
335*560*227 mm
Weight
21.6 kg
22.2 kg
Topology
High frequency isolation (for battery)
Operating ambient temperature range
-40 ~ +60°C
Ingress protection
IP66
Cooling concept
Natural convection
Intelligent redundant fan-cooling
Max. operation altitude
3000 m
Grid connection standard
NRS 097-2-1, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA, NBR 16149, NBR 16150 
Safety/EMC standard
IEC/EN 62109-1/-2, EN 61000-6-2/-3
Features
 
DC connection
MC4 plug (PV port) / Terminal Block (BAT port)
AC connection
Terminal Block
Display
LCD + Bluetooth + APP
Communication
RS485, CAN, Optional: Wi-Fi, GPRS, LAN